HI98197

Availability: In Stock

HANNA – HI98197

Ultra Pure Water EC/Resistivity Waterproof Portable Meter

The HI98197 is a rugged portable EC/TDS/Resistivity/Salinity meter with the performance and features of a benchtop. The HI98197 is supplied complete with all accessories necessary to perform high purity water measurements packaged into a durable carrying case. The accessories include a stainless steel flow cell and a threaded four ring conductivity probe that allows for high resolution 0.001 μS/cm for conductivity and 0.1 MΩ * cm for resistivity readings.

Stainless steel flow cell

Four ring conductivity/resistivity probe

 

0.001 μS/cm resolution

Product Description

HANNA – HI98197

Ultra Pure Water EC/Resistivity Waterproof Portable Meter

Specifications:-

EC Range 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)
EC Resolution 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
EC Accuracy ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)
EC Calibration automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
TDS Range 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
TDS Resolution 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)
TDS Accuracy ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)
TDS Calibration based on conductivity calibration
Resistivity Range 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resistivity Resolution 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm
Resistivity Accuracy ±1% of reading (±10 Ω or 1 digit, whichever is greater)
Resistivity Calibration based on conductivity calibration
Salinity Range % NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); natural seawater scale – UNESCO 1966: 0.00 to 80.00 (ppt)
Salinity Resolution 0.1%; 0.01
Salinity Accuracy ±1% of reading
Salinity Calibration max. one point only in % range (with HI7037 standard); use conductivity calibration for all other ranges
Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.2°C; ±0.4°F (excluding probe error)
Temperature Calibration one or two points
Temperature Compensation noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear – ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)
Measurement Modes autorange, autoend, lock and fixed range
Reference Temperature 15°C, 20°C and 25°C
Temperature Coefficient 0.00 to 10.00 %/°C
TDS Factor 0.40 to 1.00
Electrode/Probe HI763123 platinum, four ring conductivity/TDS probe with internal temperature sensor and 1 m cable (included)
Log-on-demand 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Memorized Profiles up to 10
PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type/Life 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Auto-off user selectable: 5, 10, 30, 60 min or can be disabled
Environment 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight 400 g (14.2 oz.)
Ordering Information HI98197 is supplied with HI763123 conductivity probe, HI605453 stainless steel flow cell, HI7033M 84 μS/cm calibration solution (230 mL), HI7031M 1413 μS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instructions and rugged carrying case.

Reviews

There are no reviews yet.

Be the first to review “HI98197”