HI 5522
$100.00
HANNA – HI5522
Research Grade pH/ORP/ISE and EC/TDS/Salinity/Resistivity Meter with CAL Check™
The HI5522 is an advanced research grade benchtop pH/mV/ISE/EC/TDS/Salinity/Resistivity meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5522 is rich in features including ISE incremental methods, data logging, alarm limits, comprehensive GLP, and many more while retaining simplicity in use with both dedicated key for routine operation and virtual keys that guide the user through setup options. The HI5522 ensures confidence in pH measurements with the exclusive Hanna Instruments CAL Check™ feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned.
Product Description
HANNA – HI 5522
Research Grade pH/ORP/ISE and EC/TDS/Salinity/Resistivity Meter with CAL Check™
pH SPECIFICATIONS:-
pH Range | -2.000 to 20.000 pH |
pH Resolution | 0.1, 0.01, 0.001 pH |
pH Accuracy (@25ºC/77ºF) | ±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD |
pH Calibration | automatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01,12.45) and five custom buffers |
pH Temperature Compensation | automatic or manual from -20.0 to 120.0 °C |
mV Range | ±2000 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.2 mV ±1 LSD |
Relative mV Offset Range | ±2000 mV |
EC SPECIFICATIONS:-
EC Range | 0.000 to 9.999 µS/cm, 10.00 to 99.99 µS/cm, 100.0 to 999.9 µS/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm actual EC* |
EC Resolution | 0.001 µS/cm, 0.01 µS/cm, 0.1 µS/cm, 1 µS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm |
EC Accuracy (@25ºC/77ºF) | ±1% of reading (±0.01 µS/cm) |
EC Calibration | automatic standard recognition (0.000 µS/cm, 84.00 µS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm) or user standard; single point or multi-point calibration |
TDS SPECIFICATIONS:-
TDS Range | 0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt actual TDS* (with 1.00 factor) |
TDS Resolution | 0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt |
TDS Accuracy (@25ºC/77ºF) | ±1% of reading (±0.01 ppm) |
RESISTIVITY SPECIFICATIONS:-
Resistivity Range | 1.0 to 99.9 O•cm; 100 to 999 O•cm; 1.00 to 9.99 KO•cm; 10.0 to 99.9 KO•cm; 100 to 999 KO•cm; 1.00 to 9.99 MO•cm; 10.0 to 100.0 MO•cm |
Resistivity Resolution | 0.1 O•cm; 1 O•cm; 0.01 KO•cm; 0.1 KO•cm; 1 KO•cm; 0.01 MO•cm; 0.1 MO•cm* |
Resistivity Accuracy | ±2% of reading (±1 O•cm) |
SALINITY SPECIFICATIONS:-
Salinity Range | practical scale: 0.00 to 42.00 psu; natural seawater scale: 0.00 to 80.00 ppt; percent scale: 0.0 to 400.0% |
Salinity Resolution | 0.01 for practical scale/natural seawater scale; 0.1% for percent scale |
Salinity Accuracy (@25ºC/77ºF) | ±1% of reading |
Salinity Calibration | percent scale—one-point (with HI7037 standard) |
TEMPERATURE SPECIFICATIONS:-
Temperature Range | -20.0 to 120.0 ºC**; -4.0 to 248.0 ºF**; 253.15 to 393.15 K** |
Temperature Resolution | 0.1 °C, 0.1 °F, 0.1 K |
Temperature Accuracy | ±0.2 °C; ±0.4 °F; ±0.2 K (without probe) |
Temperature Compensation | disabled, linear and non-linear (natural water) |
Temperature Coefficient | 0.00 to 10.00 %/°C |
Reference Temperature | 5.0 to 30.0 °C |
ISE SPECIFICATIONS:-
ISE Range | 1 x 10 to 9.99 x 10° concentration |
ISE Resolution | 1; 0.1; 0.01; 0.001 concentration |
ISE Accuracy @ 25 °C/77 °F | ±0.5% (monovalent ions); ±1% (divalent ions) |
ISE Calibration Points | automatic, up to five point calibration, five fixed standard solutions available (0.1, 1, 10, 100, 1000 choice of concentration) and five user defined units |
ADDITIONAL SPECIFICATIONS:-
Cell Constant | 0.0500 to 200.00 |
Cell Type | 4 cells |
Electrode/Probe | HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included); HI76312 platinum, four-ring EC/TDS probe with and 1 m (3.3’) cable (included) |
Temperature Probe | HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included) |
Profiles | up to 10, 5 each channel |
USP ?645? Compliant | yes |
GLP | calibration data including date, time, buffers used, offset and slope for pH. Cell constant, reference temperature, temperature coefficient, calibration points, calibration time stamp, probe offset for conductivity |
Logging | record: 100,000 data point storage, up to 100 lots with max. 50,000 records/lot; interval: settable between 1 second and max log time of 180 minutes; type: automatic, manual, AutoHOLD; additional: 200 records USP |
Input Channels | 1 pH/ORP/ISE + 1 EC/TDS/Salinity/Resistivity |
Display | color graphic LCD with on-screen help, graphing, and custom color configuration |
Connectivity | USB |
Environment | 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing |
Power Supply | 12 VDC adapter (included) |
Dimensions | 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”) |
Weight | 1.2 kg (2.64 lbs.) |
Ordering Information | HI5522 is supplied with HI1131 pH electrode, HI7662-T temperature probe, HI76312 conductivity probe, HI76404W electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), 12 VDC power adapter and instructions. |
Notes | *Uncompensated conductivity (or TDS) is the conductivity (or TDS) value without temperature compensation. **Reduced to actual probe limi |